1.
Clin J Gastroenterol ; 17(1): 6-11, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38032451

RESUMEN

Sublingual immunotherapy (SLIT) is an effective and popular treatment for cedar pollinosis. Although SLIT can cause allergic side effects, eosinophilic esophagitis (EoE) is a lesser-known side effect of SLIT. A 26-year-old male with cedar pollinosis, wheat-dependent exercise-induced anaphylaxis, and food allergies to bananas and avocados presented with persistent throat itching, difficulty swallowing, heartburn, and anterior chest pain 8 days after starting SLIT for cedar pollinosis. Laboratory examination showed remarkably elevated eosinophils, and esophagogastroduodenoscopy revealed linear furrows in the entire esophagus. Histological examination of an esophageal biopsy specimen revealed high eosinophil levels. The patient was strongly suspected with EoE triggered by SLIT. The patient was advised to switch from the swallow to the spit method for SLIT, and the symptoms associated with SLIT-triggered EoE were reduced after switching to the spit method. This case highlights the importance of recognizing SLIT-triggered EoE as a potential side effect of SLIT for cedar pollinosis, especially with the increasing use of SLIT in clinical practice. EoE can occur within a month after initiating SLIT in patients with multiple allergic conditions, as observed in our case. Furthermore, the spit method should be recommended for patients who experience SLIT-triggered EoE before discontinuing SLIT.


Asunto(s)
Cryptomeria , Esofagitis Eosinofílica , Rinitis Alérgica Estacional , Inmunoterapia Sublingual , Masculino , Humanos , Adulto , Rinitis Alérgica Estacional/complicaciones , Rinitis Alérgica Estacional/terapia , Inmunoterapia Sublingual/efectos adversos , Esofagitis Eosinofílica/etiología , Esofagitis Eosinofílica/terapia , Administración Sublingual
3.
Radiol Case Rep ; 17(3): 455-461, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34950273

RESUMEN

A 33-year-old woman visited our hospital due to visual loss. Her BP was 280/150 mm Hg and pulse rate was 111 beats per minute. A urinalysis showed protein in urine, suggesting kidney injury. A transthoracic echocardiography showed left ventricular hypertrophy. A Cardiac magnetic resonance imaging suggested left ventricular endocardial edema or inflammation. Ophthalmoscopy showed optic disc edema and hard exudates in both eyes. A brain MRI showed multiple high-intensity areas at the pons and white matter of the cerebrum and cerebellum. Although the patient had malignant hypertension, she was successfully treated by medication.

4.
Intern Med ; 60(14): 2245-2250, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-33612677

RESUMEN

A 73-year-old man visited our hospital due to dyspnea and epigastralgia. His plasma brain natriuretic peptide level was 1,205 pg/mL. A 12-lead electrocardiogram showed ST segment depression in leads I, V5, and V6. Transthoracic echocardiography showed dilatation and severe hypokinesis of the left ventricle. Hypertrabeculation was observed at the septum, apex, and lateral wall. Delayed enhancement of cardiac magnetic resonance imaging revealed a relatively low uptake of contrast agent at a large apical trabecula. After treatment with diuretics, follow-up echocardiography showed the disappearance of the controversial apical trabecula, which was later confirmed to have been a thrombus.


Asunto(s)
Cardiopatías Congénitas , Trombosis , Anciano , Ecocardiografía , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Trombosis/diagnóstico por imagen
6.
Radiol Case Rep ; 15(11): 2464-2470, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33014231

RESUMEN

A 27-year-old man visited our hospital after experiencing palpitations. His 12-lead electrocardiogram and chest radiograph were unremarkable. Blood test results showed normal plasma brain natriuretic peptide level (<5.8 pg/mL). Transthoracic echocardiography revealed normal left ventricular structure and function by demonstrating left ventricular wall thickness of 10 mm, end-diastolic dimension of 46 mm, end-systolic dimension of 31 mm, and ejection fraction of 64%. Pulsed-wave Doppler echocardiography demonstrated normal E/e' ratio of 7.5. Cardiac magnetic resonance imaging showed normal coronary artery. However, there was massive late-gadolinium enhancement at the mid-layer wall, suggesting massive left ventricular fibrosis. This case reveals that left ventricular function may be normal even in massive late-gadolinium enhancement. Pathophysiology other than fibrosis might have contributed to this specific finding in late-gadolinium enhancement.

9.
Radiographics ; 38(5): 1421-1440, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30207943

RESUMEN

Given the growing awareness of and concern for potential carcinogenic effects of exposure of children to ionizing radiation at CT, optimizing acquisition parameters is crucial to achieve diagnostically acceptable image quality at the lowest possible radiation dose. Among currently available dose reduction techniques, recent technical innovations have allowed the implementation of low tube voltage scans and iterative reconstruction (IR) techniques into daily clinical practice for pediatric CT. The benefits of lowering tube voltage include a considerable reduction in radiation dose and improved contrast on images, especially when an iodinated contrast medium is used. The increase in noise, which is attributed to decreased photon penetration, is a major drawback but is not as severe as that at adult CT because of the small body size of children. In addition, use of IR algorithms can suppress increased noise, yielding wider applicability for low tube voltage scans. However, a careful implementation strategy and methodologic approach are necessary to maximize the potential for dose reduction while preserving diagnostic image quality under each clinical condition. The potential pitfalls of and topics related to these techniques include (a) the effect of tube voltage on the surface radiation dose, (b) the effect of window settings, (c) accentuation of metallic artifacts, (d) deterioration of low contrast detectability at low-dose settings, (e) interscanner variation of x-ray spectra, and (f) a comparison with the use of a spectral shaping technique. Appropriate use of low tube voltage and IR techniques is helpful for radiation dose reduction in most applications of pediatric CT. Online DICOM image stacks are available for this article . ©RSNA, 2018.


Asunto(s)
Neoplasias Inducidas por Radiación/prevención & control , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos , Niño , Medios de Contraste , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Medición de Riesgo , Factores de Riesgo
10.
Br J Radiol ; 91(1085): 20170632, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29470108

RESUMEN

OBJECTIVE: To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. METHODS: We included 45 patients with renal dysfunction (estimated glomerular filtration rate  <45 ml per min per 1.73 m2) who underwent reduced-CM abdominal-pelvic CT (360 mgI kg-1, 80-kVp, SAFIRE) for oncological assessment. Another 45 patients without renal dysfunction (estimated glomerular filtration rate >60 ml per lmin per 1.73 m2) who underwent standard oncological abdominal-pelvic CT (600 mgI kg-1, 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. RESULTS: The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p < 0.01). CT attenuation and contrast-to-noise ratio of parenchymal organs and vessels in 80-kVp images were significantly better than those of 120-kVp images (p < 0.05). There were no significant differences in quantitative or qualitative image noise or subjective overall quality (p > 0.05). No significant kidney injury associated with CM administration was observed. CONCLUSION: 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Yodo , Riñón/efectos de los fármacos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste/efectos adversos , Femenino , Humanos , Riñón/fisiopatología , Enfermedades Renales/inducido químicamente , Enfermedades Renales/prevención & control , Masculino , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Radiografía Abdominal/métodos , Estudios Retrospectivos
11.
Nihon Shokakibyo Gakkai Zasshi ; 114(3): 473-482, 2017.
Artículo en Japonés | MEDLINE | ID: mdl-28260716

RESUMEN

A 53-year-old woman was referred to our hospital with a 40-mm splenic tumor, which was detected incidentally on abdominal computed tomography during hospitalization for pyelonephritis. The tumor was hypointense on T2-weighted imaging and gradually enhanced on dynamic study. The tumor increased in size over a six-month period. Since we could not exclude splenic malignancy, we performed laparoscopic partial splenectomy. Histological examination revealed multiple angiomatoid nodules with three distinct vessel types. Pathologically, the tumor was diagnosed as a sclerosing angiomatoid nodular transformation (SANT). We then examined the correlation between the imaging and pathological findings, and performed a review of previous reports, concluding that contrast-enhanced MRI was the most useful modality for diagnosing SANT.


Asunto(s)
Enfermedades del Bazo/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Imagen Multimodal , Esplenectomía , Enfermedades del Bazo/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía
12.
Neuroradiology ; 59(2): 127-134, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28050639

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the feasibility of a contrast medium (CM), radiation dose reduction protocol for cerebral bone-subtraction CT angiography (BSCTA) using 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS: Seventy-five patients who had undergone BSCTA under the 120- (n = 37) or the 80-kVp protocol (n = 38) were included. CM was 370 mgI/kg for the 120-kVp and 296 mgI/kg for the 80-kVp protocol; the 120- and the 80-kVp images were reconstructed with filtered back-projection (FBP) and SAFIRE, respectively. We compared effective dose (ED), CT attenuation, image noise, and contrast-to-noise ratio (CNR) of two protocols. We also scored arterial contrast, sharpness, depiction of small arteries, visibility near skull base/clip, and overall image quality on a four-point scale. RESULTS: ED was 62% lower at 80- than 120-kVp (0.59 ± 0.06 vs 1.56 ± 0.13 mSv, p < 0.01). CT attenuation of the internal carotid artery (ICA) and middle cerebral artery (MCA) was significantly higher on 80- than 120-kVp (ICA: 557.4 ± 105.7 vs 370.0 ± 59.3 Hounsfield units (HU), p < 0.01; MCA: 551.9 ± 107.9 vs 364.6 ± 62.2 HU, p < 0.01). The CNR was also significantly higher on 80- than 120-kVp (ICA: 46.2 ± 10.2 vs 36.9 ± 7.6, p < 0.01; MCA: 45.7 ± 10.0 vs 35.7 ± 9.0, p < 0.01). Visibility near skull base and clip was not significantly different (p = 0.45). The other subjective scores were higher with the 80- than the 120-kVp protocol (p < 0.05). CONCLUSION: The 80-kVp acquisition with SAFIRE yields better image quality for BSCTA and substantial reduction in the radiation and CM dose compared to the 120-kVp with FBP protocol.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Cráneo/diagnóstico por imagen , Anciano , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Yopamidol , Masculino , Dosis de Radiación , Estudios Retrospectivos , Técnica de Sustracción
13.
Eur Radiol ; 27(7): 2717-2725, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27966043

RESUMEN

OBJECTIVES: To retrospectively evaluate the image quality and radiation dose of 100-kVp scans with sinogram-affirmed iterative reconstruction (IR) for unenhanced head CT in adolescents. METHODS: Sixty-nine patients aged 12-17 years underwent head CT under 120- (n = 34) or 100-kVp (n = 35) protocols. The 120-kVp images were reconstructed with filtered back-projection (FBP), 100-kVp images with FBP (100-kVp-F) and sinogram-affirmed IR (100-kVp-S). We compared the effective dose (ED), grey-white matter (GM-WM) contrast, image noise, and contrast-to-noise ratio (CNR) between protocols in supratentorial (ST) and posterior fossa (PS). We also assessed GM-WM contrast, image noise, sharpness, artifacts, and overall image quality on a four-point scale. RESULTS: ED was 46% lower with 100- than 120-kVp (p < 0.001). GM-WM contrast was higher, and image noise was lower, on 100-kVp-S than 120-kVp at ST (p < 0.001). CNR of 100-kVp-S was higher than of 120-kVp (p < 0.001). GM-WM contrast of 100-kVp-S was subjectively rated as better than of 120-kVp (p < 0.001). There were no significant differences in the other criteria between 100-kVp-S and 120-kVp (p = 0.072-0.966). CONCLUSIONS: The 100-kVp with sinogram-affirmed IR facilitated dramatic radiation reduction and better GM-WM contrast without increasing image noise in adolescent head CT. KEY POINTS: • 100-kVp head CT provides 46% radiation dose reduction compared with 120-kVp. • 100-kVp scanning improves subjective and objective GM-WM contrast. • Sinogram-affirmed IR decreases head CT image noise, especially in supratentorial region. • 100-kVp protocol with sinogram-affirmed IR is suited for adolescent head CT.


Asunto(s)
Sustancia Gris/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Sustancia Blanca/diagnóstico por imagen , Adolescente , Algoritmos , Artefactos , Niño , Femenino , Humanos , Masculino , Estudios Retrospectivos
15.
Kurume Med J ; 61(1-2): 9-15, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25400236

RESUMEN

Sufficient colonic dilation is important when using CT colonography (CTC) for colorectal cancer screening. We investigated the effect of antispasmodic agents and the patient body habitus on the degree of colonic dilation in screening CTC.We assessed the effect of clinical characteristics [age, gender, body mass index (BMI), and the presence of diverticula] and the use of antispasmodics on colonic distention in 140 patients who underwent CTC for colorectal cancer screening. The CTC was performed in both the supine- and prone positions. Seventy patients received antispasmodics prior to CT examination and the other 70 did not. Colonic distention was scored using a 5-point scale: 1=collapsed, 2=poorly visualized, 3=visualized but underdistended, 4=acceptable, and 5=excellent. Images scored as 4 or 5 were considered to be of diagnostic quality. The mean visual evaluation score was significantly higher in the supine- than the prone position (4.2±0.5 vs. 4.0±0.5, p<0.01). For the supine position, only the use of antispasmodic was statistically associated with sufficient colonic dilation by univariate logistic analysis (odds ratio=2.365, p=0.03). For the prone position, age, BMI, and the use of antispasmodic were statistically associated with sufficient colonic dilation by multivariate analysis. The odds ratio of these parameters was 0.955 (p=0.02), 0.874 (p=0.03), and 2.391 (p=0.02), respectively.We obtained sufficient colonic dilation with an antispasmodic for CTC in both positions. Younger age and a lower BMI were also associated with better colonic dilation in the prone position.


Asunto(s)
Índice de Masa Corporal , Colon/efectos de los fármacos , Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Tomografía Computarizada Multidetector , Parasimpatolíticos , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Japón , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Parasimpatolíticos/administración & dosificación , Posicionamiento del Paciente , Valor Predictivo de las Pruebas , Posición Prona , Estudios Prospectivos , Factores Sexuales , Posición Supina
16.
Magn Reson Med Sci ; 13(1): 1-6, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24492735

RESUMEN

PURPOSE: Differences in acute adverse reactions to different gadolinium (Gd)-based contrast agents have not been thoroughly evaluated. We investigated the relationships among the incidence and severity of acute adverse reactions, backgrounds of patients, and 4 types of different Gd-based contrast agents (gadopentetate dimeglumine, gadoteridol, gadoterate meglumine, and gadoxetate disodium). MATERIALS AND METHODS: We retrospectively reviewed the radiological records of 10,595 consecutive patients (4,343 female; 6,252 male; mean age, 63.8 ± 14.0 years) who underwent contrast-enhanced magnetic resonance imaging between August 2006 and March 2011. Adverse reactions were classified as mild, moderate, and severe according to the definition of the American College of Radiology. The incidence of adverse reactions were compared on the basis of clinical characteristics and type, dose, and delivery methods of contrast agents by univariate and multivariate logistic regression analyses. RESULTS: The incidence of overall reactions was 0.45% (48/10,595); 45 reactions were mild and three were moderate. No severe reactions were observed. Although the incidence of adverse reactions did not differ significantly between male and female patients, younger individuals were at higher risk for acute adverse reactions. The contrast injection rate and contrast dose were not significantly related to the incidence of adverse reactions. The incidence of adverse reactions was significantly higher for gadoxetate disodium (0.82%) than gadopentetate dimeglumine (0.43%). CONCLUSION: The incidence of acute adverse reactions elicited by Gd-based contrast agents injection was only 0.45%. Younger age was a risk factor for acute reactions. All 4 agents were found to be safe, although gadoxetate disodium showed a relatively higher incidence of adverse reactions.


Asunto(s)
Medios de Contraste/efectos adversos , Imagen por Resonancia Magnética , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Medios de Contraste/química , Femenino , Gadolinio/efectos adversos , Gadolinio DTPA/efectos adversos , Compuestos Heterocíclicos/efectos adversos , Humanos , Masculino , Meglumina/efectos adversos , Persona de Mediana Edad , Compuestos Organometálicos/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
17.
Jpn J Radiol ; 32(4): 205-10, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24477527

RESUMEN

PURPOSE: The purpose of our study was to evaluate the morphology of the lumbosacral spine, i.e. the dura and vertebral body shape, of Japanese patients with Marfan syndrome (MFS) by comparing it with sex- and age-matched controls. MATERIALS AND METHODS: Spinal MR or CT images of 32 MFS patients and 32 controls were retrospectively reviewed. The anteroposterior dural sac diameter (DSD), anteroposterior vertebral body diameter (VBD), and vertebral body height (VBH) were measured from L1 to S1 levels and the dural sac ratio [DSR = (DSD/VBD)] and vertebral body aspect ratio [VAR = (VBH/VBD)] were calculated. RESULTS: At each level, mean DSD and DSR were significantly higher in MFS patients; VBD was not. The cutoff values for DSR to differentiate between MFS patients and the controls were 0.59, 0.46, 0.42, 0.45, 0.47, and 0.47 from the level of L1 to S1. At a sensitivity of 93.8 % and a specificity of 84.4 % the cutoff value at S1 was most diagnostic. In MFS patients VAR was significantly higher at L3 and L4. CONCLUSION: Our cutoff value for DSR >0.47 at S1 may help to identify MFS in the Japanese population. A square-like appearance of the L3 and L4 vertebral bodies is a supplementary finding in MFS patients.


Asunto(s)
Síndrome de Marfan/diagnóstico , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/patología , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Japón , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
18.
Jpn J Radiol ; 31(9): 600-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23771696

RESUMEN

PURPOSE: To determine whether sufficient pre-surgical treatment information of unruptured intracranial aneurysms can be obtained by using 320-row detector CT angiography (CTA) alone. MATERIALS AND METHODS: We enrolled 40 consecutive patients with unruptured intracranial aneurysms. All patients were prospectively conducted to perform 320-detector CTA as the only preoperative modality. Two blinded readers independently assessed CTA images. Interobserver agreement and the agreement between CTA and surgical findings were determined by calculating the κ coefficient. The referring neurosurgeons judged the usefulness of the information provided by CTA for treatment decisions. RESULTS: All patients had surgery without intraarterial digital subtraction angiography. Agreement between CTA and surgical findings was excellent for the aneurysm location (κ = 1.0) and good for the shape (κ = 0.71), neck (κ = 0.74) and its relationship with adjacent branches (κ = 0.71). Information obtained with 320-detector CTA was highly useful for surgical treatment in 37 of 40 (93 %) patients, although small perforators deriving from the aneurysm in 2 cases were not fully visualized on CTA images. CONCLUSION: In most patients with unruptured intracranial aneurysms, sufficient pre-surgical treatment information can be obtained by using 320-detector CTA alone.


Asunto(s)
Angiografía Cerebral/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Cuidados Preoperatorios/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/cirugía , Yopamidol , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados
19.
Acta Radiol ; 53(7): 714-9, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22821957

RESUMEN

BACKGROUND: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. PURPOSE: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. MATERIAL AND METHODS: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. RESULTS: Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CONCLUSION: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Adulto , Anciano , Biopsia , Catárticos/administración & dosificación , Distribución de Chi-Cuadrado , Pólipos del Colon/patología , Colonoscopía , Medios de Contraste/administración & dosificación , Diatrizoato de Meglumina/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polietilenglicoles/administración & dosificación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad
20.
Heart Vessels ; 26(4): 392-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21132306

RESUMEN

The purpose of this study was to evaluate the morphology and composition of atherosclerotic coronary plaques in patients with stable coronary artery disease by 64-row multidetector computed tomography (CT) angiography. A total of 56 patients were divided into an ischemia-related (n = 31) and a nonischemia-related lesion group (n = 25) based on myocardial perfusion scintigraphy, invasive angiography, and 1-year clinical follow-up. The 56 lesions detected by CT imaging were analyzed; the severity of stenosis, the lesion length, CT attenuation value, and calcium deposition of the plaques were evaluated. Clinical characteristics and CT findings were compared using univariate and multivariate logistic regression analyses. Ischemia-related lesions exhibited a greater severity of coronary stenosis, were longer (17.8 ± 8.5 vs 9.1 ± 3.9 mm), and had a higher CT attenuation value (101.7 ± 36.7 vs 81.6 ± 32.6 HU) and larger calcium deposition. By univariate logistic analysis, severity of stenosis, lesion length, CT attenuation value, and calcium deposition were significantly associated with ischemia-related plaques. The odds ratio (OR) of these parameters was 6.874 (P = 0.007), 1.371 (P = 0.001), 1.018 (P = 0.044), and 5.400 (P = 0.004), respectively. By multivariate logistic analysis, the severity of stenosis and lesion length were significantly associated with ischemia-related plaques (OR 7.588, P = 0.036 and OR 1.365, P = 0.003, respectively). In conclusion, coronary CT angiography is useful for the identification of morphological differences between ischemia-related and nonischemia-related plaques in patients with stable coronary artery disease.


Asunto(s)
Angina de Pecho/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Angina de Pecho/etiología , Calcinosis/diagnóstico por imagen , Distribución de Chi-Cuadrado , Estenosis Coronaria/complicaciones , Femenino , Humanos , Japón , Modelos Logísticos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Imagen de Perfusión Miocárdica , Oportunidad Relativa , Placa Aterosclerótica/complicaciones , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS